QC Instruments and UV Supplies
Item Description Miltec P/N
Cross Hatch Cutter, Fine Blade, Adhesion Test, .04 in (1.0mm) spacing, 11 teeth 013-02100
Cross Hatch Cutter, Med Blade, Adhesion Test Kit .06 in (1.5mm) spacing, 11 teeth 013-02200
Cross Hatch Cutter, Coarse Blade, Adhesion Test, .08 in (2.0mm) spacing, 6 teeth 013-02300
Tape, replacement roll, 1" X 72 yds. 013-02350
 
Glossmeter, 45° angle 013-00900
Glossmeter, 60° angle 013-01000
Tri-Glossmeter, 20°, 60°, 85° geometry in one unit 013-01100
   
 
Color Guide

Stores up to 200 standards with tolerances and 999 samples in the color-guide's memory and control color whenever and wherever it is needed
013-03300
 
Taber Abraser, model 5130

Built-in automatic counter and stop watch, 2 auxiliary weights (1000g load), 2 auxiliary weights (500 g load), specimen holder, 4¼" O.D., hold-down ring for specimen hold, hex wrench, 100 discs for refacing calibrase wheels, long-handle brush, 10 specimen plates 4 n.sq., 1 pr. calibrase wheels, 1 pr. calibrade wheels, vacuum unit with suction hose and variable suction, control clean up brush.
013-00010
 
Accudyne Test

Specify any combination of dyne levels and quantities you require. (minimum order eight pens)
013-03200
Magnehelic Pressure Differential Gauge

Optional Accessory Kit: -  Kit includes carrying case, 2 hose fittings and 9 feet of rubber hose
055-00200

(Accessory Kit)
055-00240
 
Lamp Tester, model BD-10AS

The electronic lamp tester determines if a UV or fluorescent lamp is defective. Simply plug the unit into a standard wall socket and touch the probe to the end of the lamp. If the lamp is good, it will have a purple glow. This tests the seal of the lamp to assure the gases have not leaked out and the vacuum is intact.
014-00010
 
014-00010 Microwave Leakage Tester, model HI-1801

The HI-1501 and HI-1801 are the most popular microwave survey meters and are acceptable to the US Government (CDRH/FDA/DHHS) for compliance testing of microwave ovens. These devices are excellent for microwave leakage testing of microwave powered UV irradiators such as Miltec ML-400, Fusion UV or Nordson UV.
055-00103
 
Microwave Leakage Tester, model HI-1501

These units are virtually immune to failure caused by excessive fields. Three ranges offer measurements from .01 to 100mW/cm² at 2450 MHz. Battery Powered.
055-00105
 
Contact Tachometer

Digital tachometer measures FPM (feet per minute), MPM (meters per minute) and RPM (revolutions per minute). Can be used to measure conveyor speed, web speed and motor shaft RPMs.
014-00100
 
CFM Thermo Anemometer

The heavy duty mini vane CFM Thermo Anemometer is an ideal instrument for measuring air flow in UV systems. Air flow is critical when operating a UV lamp; too much air flow causes over-cooling instability and not enough air flow causes hardware damage.
014-00250
 
Doctor blade, 57” x 2” x .006” 160-05100
Doctor blade, 57” x 2” x .008” 160-05200
Doctor blade, 57.4375” x 2” x .008” 160-05210
Doctor blade, 58.625” x 2” x .008” 160-05220
Doctor blade, 28.5” x 2.75” x .010” 160-05300
Doctor blade, 58” x 1.75” x .010” 160-05310
Doctor blade, 58.5” x 2.75” x .010” 160-05350
Doctor blade, 23.75” x 2” x .0425” 160-05500
Doctor blade, 27.5” x 2” x .0425” 160-05525
 
Ni-Chrome Wire, resistant to UV lamp temperatures, does not interfere with UV output, 1800°C melting point, .032" diameter (other sizes available).

1/4 lb. spool (approx. 80ft.)
010-00360
Flexible Exhaust Hose, High Temperature, UV Resistant

These are flexible, durable lightweight hoses - built to last! All are strip wound, using a polyester fabric coated on both sides with layers of neoprene and reinforced with a carbon steel wire helix. They provide superior chemical and abrasion resistance, and are certified to conform to UL-94-0 by Underwriters Laboratories.
067-00116
 
Quartz Plate Filters (custom cut)

Miltec quartz plate glass is made from the highest grade material available in the market. It provides an excellent barrier between the lamp and substrate for use with nitrogen inerted environments or as physical protective barrier against contaminates.
Call for sizes
 
Quartz Water Tubes (38mm and 45mm O.D.)

Available lengths (mm): 1118, 1173, 1310, 1321, 1393, 1656, 1860
Call for sizes
 
Gasket, sheet, 24" x 24" x .0125" 015-04320
Gasket, sheet, 24" x 24" x .0625 015-04300
Gasket, roll, 1" x .025" x 25’ 015-60337
 
Light Tight Louver

Light tight louver material is used to shield UV and visible light from a UV curing chamber area, while at the same time, allowing air flow to freely pass through the louver unimpeded.  Standard sheet size is 36" x 48".

Custom cut sizes are available.
028-76000
 
Model SLB Nitrogen Inerted Portable UV Curing Chamber

If you are considering or developing chemistry that has improved properties when UV cured in an oxygen-free environment, the SLB will allow you to get into this field for a minimal investment compared to a nitrogen inerted conveyor.
013-05000
 
UV Lamp and Reflector Cleaner

Cleans in seconds. leaves no film. Removes grime, tape residue, contaminates from reflector liners. Non-caustic; non-flammable. Non-ammonia formula dries fast. Meets C.A.R.B.(California Air Resource Board) standard for VOC emissions.
062-00015
 
Cotton Gloves

Cotton gloves, 1 Case, (10 ) packages, 12 pairper package
062-00032
 
Lint-Free Wipes

Wipes, lint free, 1 Case, (200) wipes per case, each wipe is 12" x 23"
062-00065
 
Hand Soap

Miltec soap scrubbers are softer than the skin. By using Miltec soap, your skin will be returned to the proper moisture level. Miltec soap has no harsh chemical odors and is the strongest hand cleaner concentrate possible
170-60552